Tech Applications
Tech Applications
Tech Applications

Shielding Clips vs. Soldered Shield Cans: Why Engineers Choose SMT Clip-On Solutions

2026-11-16 268

Shielding Clips vs. Soldered Shield Cans: Why Engineers Choose SMT Clip-On Solutions
In PCB design, EMI shielding is not the only consideration. Engineers also need to think about what happens when components beneath a shield require testing, inspection or repair. The way a shield can is mounted can make a significant difference to how easily these tasks can be carried out.

A conventional shield can is typically soldered directly to the PCB, providing a fixed shielding enclosure. While this approach works well for assemblies that rarely require internal access, it can make maintenance more difficult. An alternative is to use SMT shielding clips, which remain soldered to the PCB while allowing a compatible shield cover to be removed when needed.

This article compares shielding clips with conventional soldered shield cans, explaining how the two mounting approaches differ, where removable clip-on solutions are useful, and what engineers should consider when selecting an SMT shielding clip.

Traditional Shield Can Mounting on PCBs

A conventional shield can is a metal cover placed over sensitive components to form a local EMI shielding enclosure. It is commonly soldered to grounded pads or a continuous grounded area around the protected section, making it a fixed part of the PCB assembly.

This direct-mount approach requires no additional retaining clips and works well in compact, high-volume products where the shielded area is unlikely to need access after assembly.

The Maintenance Challenges of Soldered Shield Cans

Problems arise when components beneath the can need to be inspected, tested or replaced. A soldered cover blocks direct access to the shielded area, so even a relatively small repair may require removing the entire cover first.

Removing the can typically involves localized heating, solder-joint cleanup and careful handling to protect nearby components from excess heat. The cover must then be soldered back into place, adding another operation and the possibility of cover distortion, PCB pad damage or poor grounding. These risks do not make soldered cans unsuitable; they simply make service access an important design decision.

How SMT Shielding Clips Make Shielding Covers Removable

An SMT shielding clip creates two physical interfaces within the assembly:

  • PCB interface: the clip is soldered to a defined PCB land and stays with the board.
  • Can interface: the clip provides a retaining feature for a compatible shield can, allowing the cover to be secured and removed when the design permits.

During testing or rework, engineers can remove a compatible cover without desoldering the clips from the PCB. This makes the shielded area easier to access while leaving the board-mounted components in place.

A PCB shielding clip does not automatically improve shielding effectiveness. Final performance still depends on the can, grounding path, contact force, surface finish and the quality of the clip-to-can engagement. A clip-on assembly with poor contact or a loose cover offers no inherent advantage over a well-designed soldered can.

Where Clip-On Shielding Solutions Add Value

Clip-on designs are particularly useful in products where engineers need regular access to the shielded area, such as:

  • Engineering prototypes that require repeated probing or component changes.
  • Products with connectors, calibration points or displays beneath the shield.
  • Assemblies that may need local repair without removing a soldered cover.
  • PCB layouts that can place the clip within an existing SMT process while keeping the can separate.

If the shielded area will never be accessed, a soldered can may avoid extra parts and tolerance stack-up. The decision depends on how often the shield needs to be removed, how much PCB space is available and whether the selected can and clip are mechanically compatible.

Key Considerations for Selecting an SMT Shielding Clip

Mechanical compatibility comes first. Check the clip dimensions, PCB land pattern, spring characteristics and shield-can geometry to ensure that the cover engages securely and can be removed as intended. The clip must also be positioned accurately, with enough clearance for the cover to be installed and removed.

Material and plating should be checked against the intended operating environment and assembly process. Check the supplier's specifications for solderability, corrosion resistance and the recommended reflow conditions. For products exposed to humidity or cleaning processes, verify the plating specification rather than judging it by appearance.

Kinghelm KH-PBJ-151213 shielding clip for PCB shielding can retention
Kinghelm KH-PBJ-151213 shielding clip

The Kinghelm KH-PBJ-151213 is one example of a compact PCB-mounted shielding clip. Its published specifications include:

Specification Published Value
Dimensions L1.5 × W1.20 × H1.30 mm
Material SUS301 stainless steel
Material Thickness 0.15 ± 0.005 mm
Plating Nickel underlayer: 50–80 µin min; outer tin: 80–100 µin min
Mechanical Life Test More than 20,000 cycles
Spring Force Requirement 60–80 gf

The drawing defines the clip dimensions and solder-land reference, but not the matching can. Confirm the can profile, engagement and removal force with the shield-can supplier. The specified spring force of 60–80 gf applies to the clip itself, not to the force required to remove the shield can. Similarly, the 20,000-cycle figure is the mechanical life requirement specified on the clip drawing, not a verified mating life for the complete clip-and-can assembly. Review the current KH-PBJ-151213 datasheet with the selected can drawing.

When access matters, an SMT shielding clip can make a PCB shield easier to test, inspect and service without repeatedly soldering the cover. Kinghelm can help compare clip dimensions and PCB footprints and direct buyers to the appropriate shielding clip series. Contact Kinghelm with the required size, assembly method and shield-can interface.